Description
Product Name:
HIMA F8652E Safety I/O Module
Product Description:
The HIMA F8652E is a safety I/O module designed for use in safety-critical applications, particularly in industries such as oil & gas, chemical processing, power generation, and other high-risk industrial environments. The module typically integrates into HIMA’s safety system architecture to manage and process safety-related I/O signals. It works within the framework of functional safety standards such as IEC 61508 and IEC 61511 and is part of HIMA’s overall solution for implementing SIL (Safety Integrity Level) rated functions.
Product Parameters and Specifications:
Here are typical parameters and specifications you may find for such modules:
- Module Type: Safety I/O Module
- Bus Interface: Typically Profibus DP, Modbus, or HIMA’s proprietary protocols
- Signal Inputs:
- Digital Inputs: Typically 16 to 32 channels (could be binary, depending on the configuration)
- Analog Inputs: May include 4-20mA or voltage signals, depending on the model
- Input Types: Can include NAMUR sensors, dry contacts, and other typical industrial signal formats
- Signal Outputs:
- Digital Outputs: Typically 16 to 32 channels, usually relay or transistor outputs
- Analog Outputs: Depending on the configuration (e.g., 4-20mA)
- Power Supply: Typically 24V DC (may vary depending on the specific product)
- Temperature Range: Typically from -20°C to +60°C (may vary depending on environmental conditions)
- Mounting: DIN rail mounting
- Protection: IP20 or IP65 (depending on the configuration)
- Standards Compliance:
- IEC 61508 (SIL 3 capable)
- IEC 61511
- EN 61131-2 (for programmable logic controller (PLC) modules)
- ATEX or other relevant safety certifications (if used in explosive environments)
Product Use:
The HIMA F8652E module is used in safety applications where reliable monitoring and control of process variables (temperature, pressure, flow, etc.) are required to ensure the protection of personnel, equipment, and the environment. Typical uses include:
- Safety Instrumented Systems (SIS): For implementing safety functions such as Emergency Shutdown (ESD), Process Shutdown (PSD), and Fire and Gas Detection (F&G).
- Industrial Automation: Used in combination with other HIMA systems to provide high-integrity safety monitoring for critical processes.
- Oil & Gas: In offshore platforms, refineries, pipelines, etc., to ensure safety functions like pressure relief, gas leak detection, etc.
- Chemical and Pharmaceutical: Ensuring process safety for high-risk processes like reactors, distillation columns, and tanks.
- Power Generation: Critical for monitoring and controlling safety functions in nuclear, thermal, and renewable power plants.
GE IC610CHS110 |
IC610CHS130 GE PLC |
IC610CHS134A GE |
IC610CPU101C GE PLC |
GE IC610CPU104 PLC |
GE IC610MDL107B CPU |
IC610MDL112A GE CPU |
GE IC610MDL124A PLC |
GE IC610MDL125A CPU |
IC610MDL125B GE I/O |
PRD-0064DC-40-00 KOLLMORGEN PLC |
KOLLMORGEN PRD-P303250Z-35 |
PRD-P310250Z-55 KOLLMORGEN PLC |
BJRL-20012-110001 KOLLMORGEN |
CR06200-000000 KOLLMORGEN PLC |
PRD-P320260Z-C2 KOLLMORGEN PLC |
LE03565 KOLLMORGEN PLC |
IC610MDL126A PLC |
IC610MDL129A GE PLC |
IC610MDL151 PLC |
- Email: sales@plcfcs.com
- Phone:+86 15343416922
- Wechat:+86 15343416922
PLC : Allen Bradley , Siemens MOORE, GE FANUC , Schneider
DCS : ABB ,Honeywell, Invensys Triconex , Foxboro , Ovation,YOKOGAWA, Woodword, HIMA
TSI : Triconex , HIMA , Bently Nevada , ICS Triplex
Complete service we offer
Payment: T/T
Delivery: 1-2 days
Shipment: DHL UPS FedEx, etc
After-sales service: Yes, 24/7 hours